Example 1 - Calculating the stability of steel column pinned at both ends and subjected to an axial compressive load
A W12 x 50 is used as a column to support an axial compressive load of 200 kips. The length is 22', and the ends are pinned. Investigate the member for stability without regard to load or resistance factors.